当前位置:首页> 产品

NaM601001_Lolina Advanced qPCR SYBR Master Mix_11185-Lolina

NaM601001_Lolina Advanced qPCR SYBR Master Mix_11185

    详细说明

    Lolina A/S

    Address: Sindalsvej 30 8240 Risskov Danmark 

                        Email: Info@lolina.dk

     Website: https://lolina.dk


    Product Information

     

    Product name

    Lolina® Advanced qPCR SYBR Master Mix

    Cat.No.

    NaM601001

    Size

    1 mL/5×1 mL/50×1   mL/100×1 mL

     

     

    Storage and shipping

    1. The product is shipped with ice pack.

    2.  The product can be stored at -15℃ ~ -25℃ for 18 months.

    3. The product contains fluorescent   dyes, so it is necessary to avoid strong light irradiation   when storing or preparing the   reaction system.

     

     

     

     

     

    Application equipment

    ABI: 7500, 7500 Fast, ViiA7,   QuantStudio1, 3 and 5, QuantStudio 6,7, 12k Flex;

    Stratagene: MX3000P, MX3005P,   MX4000P;

    Bio-Rad: CFX96, CFX384,   iCycler iQ, iQ5, MyiQ, MiniOpticon,   Opticon,Opticon 2, Chromo4;

    Eppendorf: Mastercycler ep realplex, realplex 2 s;

    Qiagen: Corbett Rotor-Gene Q, Rotor-Gene   3000, Rotor-Gene 6000;

    Roche Applied Science: LightCycler 480, LightCycler 2.0, Lightcycler 96;

    Thermo Scientific: PikoReal Cycler; Cepheid: SmartCycler; Illumina: Eco qPCR

     

     Product description

     

    Lolina® advanced qPCR SYBR Master Mix is a pre-solution for real-time quantitative PCR amplification.  It  has  the  characteristics  of  high   fluorescence  intensity,  high   sensitivity  and specificity, and high amplification yield. It is blue in color and has the function of sample addition tracer. The core component Lolina® Taq DNA polymerase uses an antibody method to hot-start, which  can  effectively  suppress  non-specific  amplification  caused  by  primer  annealing  during sample preparation. At the same time, the formula adds a factor to improve the PCR reaction amplification  efficiency  and  a  promotion  factor  to  balance  the  amplification  of  genes  with


     

    different GC contents (30~70%), so that quantitative PCR can obtain a good linear relationship in a wide quantitative range.

    Operate

     

    qPCR reaction System

     

    Components

    Volume μLc)

    Volume μLc)

    Final Conc.

    Lolina® Advanced qPCR SYBR Master Mix

    10

    25

    1 ×

    Forward Primer (10 μmol/L)a)

    0.4

    1

    0.2 μmol/L

    Reverse Primer (10 μmol/L)b)

    0.4

    1

    0.2 μmol/L

    DNA/cDNA templateb)

    -

    -

    -

    ddH20

    Up to 20

    Up to 50

    -

    [Note]:

    a) Primer concentration: The final primer concentration is 0.2 μmol/L, and can also be adjusted between 0. 1 and 1.0 μmol/L as appropriate.

    b) If the template is undiluted cDNA stock solution, the volume used should not exceed  1/10 of the total volume of the qPCR reaction. The optimal amount of template added is to ensure that the Ct value obtained by amplification is within 20-30 cycles.

    c) It is recommended to use 20 μL or 50 μL to ensure the effectiveness and reproducibility of target gene amplification; mix thoroughly before use on the machine to avoid excessive bubbles caused by vigorous shaking.

     


    Reaction   ro  ram


     

    Cycle step

    Temp.

    Time

    Cycles

    Initial denaturation

    95 °C

    2 min

    1

    Denaturation

    95 °C

    10 sec

    40

    Annealing/Extensiona)

    60 °C

    30 secb)

    Melting curve stagec)

    Instrument Defaults

    1


    [Note]:

    a) Annealing temperature and time: Please adjust according to the length of primer and target gene.

    b) Fluorescence signal acquisition: Please set the experimental procedure according to the requirements in the instructions for use of the instrument. The time setting of several common instruments is as

    follows:

    20 secApplied Biosystems 7700, 7900HT, 7500 Fast

    31 secApplied Biosystems 7300

    32 secApplied Biosystems 7500

    c) Melting curve: The instrument default program can be used normally.

     

    Primer Design Guide

     

    1. The recommended primer length is about 25 bp. The optimal length of the amplified product is  150bp, and can be selected from 100 bp to 300 bp.


    2. The difference in Tm values of forward primer and reverse primer should not exceed 2 °C. The optimal primer Tm value is 60 - 65 .

    3. The primer bases should be distributed evenly to avoid 4 consecutive identical bases, and the GC content should be controlled at around 50%. The last base at the 3’ end is preferably G or C.

    4. It is best to avoid complementary sequences of more than 3 bases within the primer or between the forward and reverse primers.

    5. Primer  specificity needs to be checked using the NCBI BLAST program, to avoid non-specific complementarity of more than 2 bases at the 3 ’ end of the primer.

    6. The designed primers need to be tested for amplification efficiency. Only primers with the same amplification efficiency can be used for quantitative comparative analysis.

     

    Notes

     

    1. For your safety and health, please wear lab coats and disposable gloves for operation.

    2. After thawing, the Master Mix may appear flocculent or white precipitate. Dissolve it slowly by hand and mix it gently by inverting it up and down until the solution is clear. It will not affect the performance of the reagent.

    3.  It is recommended to use our companys cDNA synthesis kit (Cat. No.: NaM502002) to effectively remove residual genome from RNA samples.

    4.  If electrophoresis is required, in order to obtain clear bands, it is recommended to dilute the qPCR product 20 - 30 times before electrophoresis.

    5. This product is for research use ONLY


    产品详细信息请联系产品工程师